"Quality, know-how and on-time delivery will always satisfy our customers"
Many things have changed in the past and many things will change in the future, but our target will always remain the same.
You are here
Groth Corporation - Industrial product selection guide
GROTH CORPORATION - a Continental Disc company
PRODUCT OVERVIEW
The following information provides a brief summary of Groth industrial products. If you need more details on applications, features, benefits and technical information for each model, it can be found on our Groth product page - click on the pdf for the full product selection guide.
- PRESSURE/VACUUM RELIEF VALVES
Pressure/vacuum relief valves are protection devices typically mounted on a nozzle opening on the top of a fixed roof atmospheric storage tank. Their primary purpose is to protect a tank against rupture or implosion by allowing the tank to breathe, or vent, when pressure changes in the tank due to normal operations.
Technical data: Groth Corporation Series 1400 - Pilot Operated Pressure/Vacuum Relief Valve.
Technical data: Groth Corporation Series 1200A - Vent to Atmosphere Pressure/Vacuum Relief Valve.
Technical data: Groth Corporation Series 1220A - Pipe-Away Pressure/Vacuum Relief Valve.
Technical data: Groth Corporation Series 1260A - Pipe-Away Pressure Relief Valve.
Technical data: Groth Corporation Series 1300A - Vacuum Relief Valve.
Technical data: Groth Corporation Series 1360A - Vacuum Relief Valve (Side Mount).
Technical data: Groth Corporation Series 2300A - Pressure Relief Valve.
Technical data: Groth Corporation Model 8800A - Vent to Atmosphere Pressure/Vacuum Relief Valve & Flame Arrester Combination.
Technical data: Groth Corporation Model 8820A - Pipe-Away Pressure/Vacuum Relief Valve & Flame Arrester Combination.
Technical data: Groth Corporation Models 1720A & 1760A - Pipe-Away Pressure/Vacuum Relief Valve Same Size I/O.
Technical data: Groth Corporation Series 1800A - 10% Overpressure Pressure/Vacuum Relief Valve.
Technical data: Groth Corporation Series 1500 - Air Operated Pressure/Vacuum Relief Valve.
Technical data: Groth Corporation Fiberglass Plastic Relief Valve.
Technical data: Groth Corporation Steam Jacketed Relief Valve.
- PILOT OPERATED RELIEF VALVES
Pilot operated relief valves serve the same primary purpose as pressure/vacuum relief valves, but with better performance characteristics than weight or spring loaded valves. Lower leakage and better flow performance make a pilot operated valve the solution when the focus is product conservation, expanded tank working pressure range, and reduced fugitive emissions. A pilot operated relief valve provides the maximum available leakage control technology as specified in the Clean Air Act of 1990.
Technical data: Groth Corporation Series 1660A - Pressure Relief Pilot Operated Valve.
Technical data: Groth Corporation Series 1400 - Pilot Operated Pressure/Vacuum Relief Valve.
- EMERGENCY RELIEF VALVES
Emergency relief valves protect tanks against excessive pressure caused by external fire exposure or flashes within the tank. Emergency relief valves provide higher flow capacity than standard pressure/vacuum relief valves.
Technical data: Groth Corporation Series 2300A - Pressure Relief Valve.
Technical data: Groth Corporation Series 2000A - Emergency Relief Valves.
Technical data: Groth Corporation Model 2100 - Emergency Relief Valve.
- DEFLAGRATION FLAME ARRESTERS
Deflagration flame arresters are fire safety devices used to protect stored or process media from deflagrations. A deflagration flame arrester can be used on the top of a tank in certain conditions, as an in-line safety device where combustible gases are transported through low pressure pipe lines.
Technical data: Groth Corporation Model 7618 - Vertical Deflagration Arrester.
Technical data: Groth Corporation Model 7628 - Horizontal Deflagration Arrester.
Technical data: Groth Corporation Model 7622B - Deflagration Arrester.
- DETONATION FLAME ARRESTERS
Detonation flame arresters provide flame protection in cases where the ignition source pipe lengths are greater than what can be protected with a deflagration arrester.
Technical data: Groth Corporation Model 7658A - Detonation Flame Arrester.
Technical data: Groth Corporation Model 7661 - Detonation Flame Arrester.
Technical data: Groth Corporation Model 7758A - Detonation Flame Arrester.
- BLANKET GAS REGULATORS
Blanket gas regulators can provide both pressure and fire protection for storage tanks by supplying a blanketing gas which maintains a constant positive pressure in the vapor space of a storage tank.
Technical data: Groth Corporation Series 3000 - Blanket Gas Regulator.
- MORE...
Technical data: Groth Corporation Model 12-TH - Thief Hatch.
Technical data: Groth Corporation Models 6000/6100 - Gauge Hatch.
Technical data: Groth Corporation Model 210 - Test Stand.
QUALITY AND CERTIFICATIONS
Groth Corporation products are designed to the latest standards from around the world. Groth possesses in-house flow lab testing capabilities which have been certified by an independent authority and are capable of flow testing products to API 2000 standards. Additionally, Groth has the capability of performing deflagration and detonation testing as per U.S. Coast Guard 33 CFR and ISO 16852 (ATEX) guidelines. Groth has worked with outside testing and approval agencies such as Southwest Research, TUV and IBExU to ensure that products perform to relevant specifications. As an ISO 9001 approved company, including compliancy to the European Pressure Equipment Directive (PED) through testing and certifications, Groth is able to meet the customer’s demanding requirements for performance, safety and consistent quality.
MORE INFO NEEDED? Visit our Groth product page to find the full product selection guide (pdf).